Error Codes
Table 4
33
PROBLEM
• Error 1
• Error 2
• Error 11
• Error 12
• Error 21
• Error 22
• Error 23
• Error 31
Elevation
Motor
Error
Motor drive
error
CAUSE / SOLUTION
Acceleration is too quick in the acceleration or reached speed phase.
Possible causes: Motor drive defective or user pushing on the running belt for too long.
Running belt not following the speed required in the reached speed phase.
• Possible causes: Deck too sticky. Walk on deck for 15 minutes at 4 mph.
• Motor drive board can be defective.
Check speed sensor or optical disk.
Acceleration is too fast during acceleration phase.
Possible cause: Defective drive board.
Acceleration is too slow during acceleration phase.
Possible causes: Deck too sticky.
Walk on deck for 15 minutes at 4 mph.
Speed sensor problem.
In a deceleration phase, the speed slows down too fast.
Possible cause: Drive board defective.
• In a deceleration mode, the speed slows down too slowly.
Possible cause: Drive board defective, speed sensor problem.
There is an abnormal acceleration during the deceleration phase.
Motor drive board is defective.
Acceleration is too quick under 2 mph.
Possible causes: Motor drive defective or user pushing on the running belt for too long.
Elevation motor values from potentiometer are out of range.
Possible causes: Elevation motor is defective or uncalibrated.
Perform an elevation calibration in the diagnostics menu.
Motor drive board can be defective.
Elevation Motor not functionnal.
Elevation Motor not connected.
A problem occurred on the motor control board. Contact your Bodyguard
®
Dealer to give this
information. This will help finding the cause.